Features:
• High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier • Single & Dual channel versions with independent channels including fan, sensor and flow monitoring • Provides pre-alarm functionality for graduated alarm thresholds • Ultrasonic airflow sensing with expanded monitoring range • A single device covers up to 2,000m2 according to national design regulations • Pipe-IQ™ software provides intuitive system layout and configuration all in one package • Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring • Multiple event logging up to 2244 events • User friendly air flow pendulum graph for verification of pipe network functionality • Easily replaceable and reusable filter without affecting the rest of the device • Protected electronics from air flow and accidental damage during installation or maintenance • Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required • Easy access to parts requiring routine maintenance: filter(s) and sensor(s) • IP65 enclosure
Physical Specification:
Height: 403mm (including inlets and outlets) Width: 356mm Depth: 135mm Cable Access: 3 x M20 gland holes pre-drilled on top and bottom of the FAAST LT-200 unit Wire Gauge: 0.5mm2 to 2mm2 max Maximum Single Pipe Length: 100m Maximum Total Branched Pipe Length: 160m (per channel) Maximum Air Inlet Holes: 18 (per channel) Outside Pipe Diameter: 25mm or 27mm Internal Pipe Diameter: 15-21mm Sensitivity: 0.07 - 0.66 % obs/m (Alarm Level 1-5) Relays: 3 (1 Alarm, 1 Fault , 1 Pre-Alarm) x per channel Sounder outputs: 1 per channel Sound Performance: As low as 26db(A) Event Log: 2,244 Events Fan control: 10 programmable speeds
Electrical Specification:
Smoke Sensor(s): High sensitivity LED Detection Chamber External Supply Voltage: 18.5-31.5 V Remote Reset Time: 2s Power Reset: 0.5s Operating Current: 170mA @ 24 VDC (excluding sounders) Max Alarm Current: 360mA @ 24 VDC (excluding sounders) Relay Contact Ratings: 2.0 A @ 30 VDC, 0.5 A @ 30 VAC
Listings and Aprovals:
VdS LPCB EN54-20: (holes per channel) Class A – 3 holes Class B – 6 holes Class C - 18 holes
Internet Explorer tarayıcısının 9.0 ve daha eski sürümlerini desteklememekteyiz. Web sitemizi doğru görüntüleyebilmek için tarayıcınızı güncelleyebilirsiniz, güncelleyemiyorsanız başka bir tarayıcıyı ücretsiz yükleyebilirsiniz.